WE PROVIDE SOLUTIONS

Technical Capabilities for Multilayer PCBs

CapabilitiesMinimum CapabilityMaximum CapabilityToleranceRemarks

Metal finishing:
   Hal Lead Free (SnCuNi)
   Chemical Tin (Inm.Sn) (*)
   Chemical Silver (Inm.Ag)
   Electroless Ni Inmersion Gold (ENIG)

 

 



Ni: 3 µm
Au: 0,04 µm

 

 



Ni: 7 µm
Au: 0,07 µm 

 

 

-

 


Sn100C Alloyage
(*) Subcontracted

Final finishing:
   Liquid PhotoImageable Solder Mask
   Ink Legend
   Conductive Carbon Ink
   Peelable mask

 

 

-

 

 

-

 

 

-

 


A wide range of colours
A wide range of colours

Raw Material:
   FR-4 Tg Standard
   FR-4 High Tg


130 ºC
150 ºC

140 ºC
180 ºC

 

-

 
Depending on the manufacturer
 Number of layers 4 8 -  -

Base Copper (inner or outter layers)

17 µm 70 µm  - Under request (consult delivery time): 105 μm

Platted Through Hole (PTH)

Platted Through Hole (PTH)

200 µm - + 0,10 / - 0,05 mm Or equivalent tolerance

Non Platted Through Hole (NPTH)

Non Platted Through Hole (NPTH)

300 µm - + 0,10 / -0 mm Or equivalent tolerance

Width and isolation of copper conductors in outter layers (Base Copper)

Width and isolation of copper conductors in outter layers (Base Copper)

100 µm (17 µm)
125 µm (35 µm)
200 µm (70 µm)

 

-

 

± 25%
± 30%
± 30%

 

-

Width and isolation of copper conductors in inner layers (Base Copper)

Width and isolation of copper conductors in inner layers (Base Copper)

100 µm (17 µm)
100 µm (35 µm)
200 µm (70 µm)

 

-

± 25%
± 30%
± 30%

 

-

Copper annular ring for outter layers (Base Copper)

Copper annular ring for outter layers (Base Copper)

100 µm (17 µm)
125 µm (35 µm)
250 µm (70 µm)

 

-

 

-

 

 Recommendation: for a good soldering surface, for component holes ≥ 200 µm

Copper annular ring for inner layers

Copper annular ring for inner layers

150 µm 

-

-  -

Minimal isolation in inner layers (power and ground planes)

Minimal isolation in inner layers (power and ground planes)

 250 µm  - -  -

Distance between NPTH and copper conductor

Distance between NPTH and copper conductor

200 µm - - -

Distance between copper conductor and board edge (routed)

Distance between copper conductor and board edge (routed)

150 µm - - -

Misalignement between copper and PTH

Misalignement between copper and PTH

- - ± 100 µm -

Misalignement between outline and PTH

Misalignement between outline and PTH

 - - ± 150 µm  -

Distance between a copper conductor and theorical scoring axis

Distance between a copper conductor and theorical scoring axis

500 µm - - -

Maximum hole to be plugged with peelable mask

Maximum hole to be plugged with peelable mask

0,30 mm 1,80 mm - -

Distance between peelable mask and copper pad

Distance between peelable mask and copper pad

0,80 mm - - -

Solder mask annular ring

Solder mask annular ring

50 µm - - -

Solder mask bridge

Solder mask bridge

100 µm - - -

Distance between solder mask clearnace and copper conductor

Distance between solder mask clearnace and copper conductor

50 µm - - -

Misalignement between solder mask and copper

Misalignement between solder mask and copper

- - ± 150 µm -

Ink legend width

Ink legend width

100 µm - - -

Misalignement between ink legend and copper

Misalignement between ink legend and copper

- - ± 200 µm -

Carbon Ink width

Carbon Ink width

600 µm - - -

Separation between carbon conductors

Separation between carbon conductors

400 µm - - -

Platted wall thickness

Platted wall thickness

20 µm 60 µm - Average: 25 μm

Scoring positioning (taken on axis)

Scoring positioning (taken on axis)

- - ± 150 µm -

Core thickness after scoring process

Core thickness after scoring process

200 µm - ± 150 µm Standard: 300 µm

Misalignement between top-bottom scoring blades

Misalignement between top-bottom scoring blades

- - ± 150 µm -

Final Thickness

Final Thickness

0,80 mm 3,2 mm

± 10% (e > 1,0 mm)
± 100 µm (e ≤ 1,0 mm)

Depending on Multilayer stack-up and number of layers

Bow&Twist

Bow&Twist

- 0,75% of diagonal - -

Final pcb dimensions (routing)

Final pcb dimensions (routing)

15 x 15 mm 600 x 500 mm < 30 mm: ± 0.10 mm
< 120 mm: ± 0.15 mm
>120 mm: ± 0.20 mm
-

Other

- - - According to IPC-A-600 revision G Standard

REMARKS

1-The extra Cu deposition is performed by an electrolytic process; therefore It is extremely convenient that the density of Cu on both sides is similar. This reduces the irregularities in total Cu thickness, warping and bending, reduction in PTH diameters and the excess of Cu on conductors.
2.- It is important to eliminate nonfunctional pads on the inner layers (usually placed where PHTs go with no connection on that particular layer) in order to avoid short circuits.
3.- For class VI and VII PCBs the use of tear drops is highly recommended to compensate the quantity of Cu on both sides.

Need help?